RICOH CORP -- RICOH FT SELENIUM DRUM ("H") -- 3610-00F004887
===================== Product Identification =====================
Product ID:RICOH FT SELENIUM DRUM ("H")
MSDS Date:01/01/1987
FSC:3610
NIIN:00F004887
=== Responsible Party ===
Company Name:RICOH CORP/WEST CALDWELL, NJ 07006
Emergency Phone Num:(03) 777-8183
CAGE:EO963
=== Contractor Identification ===
Company Name:RICOH CORP/WEST CALDWELL, NJ 07006
CAGE:EO963
Company Name:RICOH CORPORATION
Address:5 DEDRICK PLACE
City:WEST CALDWELL
State:NJ
ZIP:07006-6304
Country:US
Phone:800-336-6737
CAGE:54726
============= Composition/Information on Ingredients =============
Ingred Name:SELENIUM COLLOIDAL
CAS:7782-49-2
RTECS #:VS8310000
OSHA PEL:0.2 MG/M3 (SE)
ACGIH TLV:0.2 MG/M3 (SE); 8990
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
Ingred Name:TELLURIUM (SARA III)
CAS:13494-80-9
RTECS #:WY2625000
OSHA PEL:0.1 MG/M3
ACGIH TLV:0.1 MG/M3; 9192
===================== Hazards Identification =====================
Effects of Overexposure:THERE IS NO HEALTH HAZARD IN NORMAL USE
CONDITIONS.
======================= First Aid Measures =======================
First Aid:NONE REQUIRED.
===================== Fire Fighting Measures =====================
Flash Point:NONE
Extinguishing Media:IF PRODUCT INVOLVED IN A FIRE USE
CO2/WATER/FOAM/DRY CHEM
Fire Fighting Procedures:NONE
Unusual Fire/Explosion Hazard:NONE UNDER NORMAL STORAGE AND USE
CONDITIONS.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN A COOL AND DRY PLACE. KEEP
AWAY FROM HEAT AND OPEN FLAME. KEEP CLOSED IN A PACKAGE.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE NEEDED
Ventilation:NONE NEEDED
Protective Gloves:COTTON
Eye Protection:NONE NEEDED
Other Protective Equipment:NONE NEEDED
Supplemental Safety and Health
MSDS DATE: APR 11, 83. ALUMINUM CYLINDER COATED WITH SELENIUM ALLOY.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:1270F
Spec Gravity:4.3
Solubility in Water:INSOLUBLE
Appearance and Odor:SILVERISH METALLIC, NO ODOR
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE
Hazardous Decomposition Products:NONE UNDER NORMAL HANDLING AND USE.
==================== Disposal Considerations ====================
Waste Disposal Methods:USED DRUMS SHOULD BE COLLECTED BY SERVICE
PERSONNEL. DO NOT BURN.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.